EMC laboratory
- Podrobnosti
- Zveřejněno 18. 1. 2017 9:44
The EMC laboratory is one of the two laboratories of EUROSIGNAL. Both of these gained accreditation of CAI (Czech Accreditation Institute) acc. ČSN EN ISO/IEC 17025 repeatedly in March 2014. We are performing tests of electromagnetic interference and electromagnetic immunity tests on electric as well as electronic devices.
What are we testing
Theoretically any electric or electronical device, practically only devices in accordance to standards that are in our accreditation range, see list of accredited test.
Frequently tested device:
- products intended for railway enviroment
- hospital equipment
- computer network components
Where are we testing
We are performing tests entirely in laboratories of science technology park Mstětice, our equipment does not allow us to perform tests outside.
Range of tests we can do
A. Electromagnetic interference tests (EMI)
EMI test |
Workplace parameters, |
Standarts |
measurement of electromagnetic radiated disturbances | here |
ČSN EN 55011 ČSN EN 55022 ČSN EN 50121-4 ČSN EN 61000-6-3 ČSN EN 61000-6-4 and others ... |
measurement of EMC emissions radiated by shield (input/output by shield) |
||
measurement of electromagnetic conducted disturbances |
||
measurement of interfering terminal voltage |
||
measurement of EMC leaded emissions (input/output ports) |
||
The range of all standarts according to which we are providing EMI testing, see here |
B. Electromagnetic susceptibility (EMS) tests
EMS test
Immunity tests against to ... |
Workplace parameters, |
Standarts
ČSN EN ... |
... electrostatic discharge (ESD) |
61000-4-2 |
|
... radiated, radio-frequency, electromagnetic field |
61000-4-3 |
|
... electrical fast transient/burst (EFT/BURST) |
61000-4-4 |
|
... surge impulses (SURGE) |
61000-4-5 |
|
... conducted disturbances, induced by radio-frequency fields |
61000-4-6 |
|
... power frequency magnetic field |
61000-4-8 |
|
... pulse magnetic field |
61000-4-9 |
|
... voltage dips, short interruptions and voltage variations |
61000-4-11 |
|
... variation of power frequency |
61000-4-28 |
|
... voltage dips, short interruptions and voltage variations on d.c. input power port |
61000-4-29 |
|
The range of all standarts according to which we are providing EMI testing, see here. |
Our equipment
The essencial part of the laboratory is EMC Frankonia chamber for radiation interference measuring and for immunity to HF EM field test in a three-metre distance.
For EMI tests the chamber is acompanied by kit of EMI Test Receiver, remote controlled antennas, turntable, cables and also by very user friendly meassuring software EMC32 with really well prepared graphical layout.
For EMS testing there is a second kit of generator, switching unit, two amplifiers, HF power meter, HF electric field probe and other necessary components. This kit is controlled by software CD/RF-LAB.
Other very important measuring devices in EMC Laboratory is multipurpose generator TRA 2000 IN 4 and generator of induced interferences CIT 10/75, both used for immunity tests. And we are using a number of testing tables, coupling/decoupling units (CDNs), coupling clamps, coupling planes, artifitial power networks, cable reductions, grounding attachments and other laboratory accesories.
All laboratory premises are fully airconditioned and there is a necessary workspace where the costumers can modify their products with solder station, set of ferrites for suppression of EM interferences, etc..
Our measuring systems are connected to the data network with on-line management where we are maintaining the orders, testing data and results by an internal infromation system.